ANALYSIS OF DIFFERENCES IN IMAGE QUALITY WITH VARIATIONS IN SLICE THICKNESS IN CT-SCAN BRAIN EXAMINATIONS WITH TRAUMA CASES AT THE RADIOLOGY INSTALLATION OF RSI SITI RAHMAH PADANG

Nerifa Dewilza, Sagita Yudha, Wahdini Hanifah, Livia Ade Nansih, Rahayus Septiani

Abstract


Research has been carried out on the analysis of differences in image quality with slice thickness variations in CT-Scan brain examinations with trauma cases at the Radiology Installation at RSI Siti Rahmah Padang. This study aims to determine the difference in image quality with varying slice thicknesses of 3 mm, 5 mm, and 7 mm in CT-Scan brain examinations with trauma cases and what slice thickness is capable of producing optimal image quality in establishing a diagnosis in CT-Scan brain examinations. with trauma cases. This research was conducted in January 2022 - June 2022 with a quantitative type of research with experimental methods, using purposive sampling techniques and questionnaire data distributed to respondents were processed using the weight mean score formula and the SPSS Friedman method. According to the weight mean score formula, the highest average value for the slice thickness variations of 3 mm, 5 mm and 7 mm is a slice thickness of 3 mm with an average value of 3.64, contrast resolution has an average value of 3.67, noise is 3. 49 and the results of the CT-Scan brain examination in the bone window in trauma cases had an average of t3.74. Based on the SPSS results of the Friedman method, it was found that there was a significant difference in the results of slice thickness variations of 3 mm, 5 mm and 7 mm in the CT-Scan brain examination with trauma cases because (p-value < 0.05), this shows that Hₒ was rejected and Hₐ was accepted. A good slice thickness variation for showing trauma on a CT-Scan brain examination is a slice thickness of 3 mm in the bone window, because if there is a very small fracture it can be seen more clearly.

Keywords


CT-Scan; brain; Trauma; Slice; Resolution

Full Text:

PDF

References


Bontrager, K. L. (2018). Texbook of Radiographic Positioning and Related Anatomy Ninth Edition. Elsevier.

Bushong, S. (2001). Radiologic Science for Technologists. Seventh Edition. United State of America : A Harcourt Healt Sciences Company.

Dewi, P. S., Ratini, N. N., & Trisnawati, N. L. P. (2022). Effect of x-ray tube voltage variation to value of contrast to noise ratio (CNR) on computed tomography (CT) Scan at RSUD Bali Mandara. International Journal of Physical Sciences and Engineering, 6(2), 82–90.

E, S. (2016). Computed Tomography: physical principles, clinical applications, and quality control. WB Saunders Company.

Hutami, I. A. P. A., Sutapa, G. N., & Paramarta, I. B. A. (2021). Analisis Pengaruh Slice Thickness Terhadap Kualitas Citra Pesawat CT Scan Di RSUD Bali Mandara. BULETIN FISIKA, 22(2), 77–83.

Karina, K., Natalisanto, A. I., Wardani, P. S., & Subagiada, K. (2017). Analisis Pengaruh Slice Thickness terhadap Kualitas Citra Pesawat CT-Scan.

Kartawiguna, D., & Rusmini. (2017). Instrumentasi Pemindai Tomografi Komputer.

Louk, A. C., & Suparta, G. B. (2014). Pengukuran Kualitas Sistem Pencitraan Radiografi Digital Sinar-X. Bimipa, 24(2), 149–166.

Makmur, I. W. A., Setiabudi, W., & Anam, C. (2013). Evaluasi Ketebalan Irisan (Slice Thickness) pada Pesawat CT-Scan Single Slice. In Jurnal sains dan matematika.

Neseth, R. (2000). Procedures and Documentation for CT and MRI. McGraw-Hill.

Putu, I. A., Hutami, A., Sutapa, G. N., Bagus, I., & Paramarta, A. (2021). The Analysis of the Effect of Slice Thickness of Phantom on Image Quality of CT Scan at RSUD Bali Mandara. Accreditation Starting on, 22(2), 77–83.

Sookpeng, S., Martin, C. J., & Butdee, C. (2019). The investigation of dose and image quality of chest computed tomography using different combinations of noise index and adaptive statistic iterative reconstruction level. Indian Journal of Radiology and Imaging, 29(01), 53–60.

Sugiono. (2020). Metode Penelitian Kuantitatif Kualitatif dan R&D.

Syaripudin, A. (2018). Nurse Caring Behavior On Post Craniotomy Patients At Icu Room Gunung Jati Regional Of Cirebon. Jurnal Kesehatan Mahardika, 5(1), 10–16. https://doi.org/10.54867/jkm.v5i1.25

Utami, A. P., Andriani, I., & Budiwati, T. (2018). Prosedur Pemeriksaan CT Scan Kepala Pada Kasus Cerebrovascular. Jurnal Ilmu dan Teknologi Kesehatan, 4(2), 16–19.




DOI: https://doi.org/10.33666/jitk.v15i2.643

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

  
 Published by : Widya Husada Semarang University | ISSN : 2086-8510 (Print) | ISSN : 2655-5875 (Online)
  

INDEXED BY
 
MAP LOCATION